The Model I8-M100 is a high performance, large scale incinerator.
The i8-M100 which is a larger capacity model from the range of specialist “M” incinerators which are developed for medical waste disposal. With addition of a dedicated PLC control panel, I.D. fan and increased insulation improves performance which provides all-round suitability for many different types of medical, clinical, pharmaceutical and hazardous waste solutions. This Model benefits from a secondary chamber with afterburner for the re-burn of harmful emissions with a 2 second retention time. This delivers clean and tidy, efficient waste solutions and is a beneficial return on your investment.
Typical Medical Waste Applications
- Dental / Cosmetic Clinics
- Blood Banks / Collection
- Nursing Homes
- <400 Bed Medical Facilities
- Medical Waste Collection
Technical Specifications
Operational Specs |
Physical Specs |
||
---|---|---|---|
Combustion Chamber Volume (m3) |
1.35m3 |
External Length (mm) |
2540mm |
Burn Rate* |
up to 80kg per hour |
External Width (mm) |
1100mm |
Average Fuel Consumption |
14 – 19 ltrs p/h |
External Height (mm) |
4180mm |
Operational Temperature |
> 850°C |
Door Size (mm) |
1450 x 750mm |
Gas Retention in Secondary Chamber |
2 secs |
Shipping Weight |
3100kg |
Temperature Monitoring |
Yes |
||
Average ash residue (%) |
3% |
For reference only, not to be used for installation purposes. * All burn rates are dependant on the calorific value of the waste being incinerate. Atmospheric conditions,fuel (gas/oil) quality, additonal accessories (autoloader, de-asher) can also have a major impact on actual burn rates. |
|
Thermostatic Device |
Yes |
Please Click To view and compare our models on our incinerator quick reference page
Configuration Options
All our range of incinerators are hand-built in the UK by High Quality expert time-served welders and fabricators.
For more information on our Variety of Medical & Non-Medical Incinerators
Call us now on +44 (0)7428 120 152 or use the form on our Contact Us page.