MODEL CAPACITY
(m)
MAX BURN RATES*
(kg per hour)
DIMENSIONS
(in meters)
DOOR SIZE
(in meters)
WEIGHT
(in KG)
2ND
CHAMBER

(afterburn)
GAS
TIME**

(seconds)
OPTIMAL
WASTE
LOAD

(kg per load)
OPTIMAL
WASTE
RELOAD
TIME

(mins)
FUEL
USAGE

(litres
per hr )
Animal Medical MSW RDF/SRF Cat
A&B
Wood
L W H
Sirocco 0.2 10 10 10 20 1.00 .0.80 1.64 0.57ø 70 not fitted 2 – 4 12
I8-10 0.1 15 10 15 30 0.73 0.46 1.93 0.33 x 0.33 400 not fitted 3 – 6 12 3 – 4
I8-10S 0.1 15 10 15 30 0.73 0.46 3.28 0.33 x 0.33 500 fitted as standard 0.5 3 – 6 12 3 – 4
I8-20 0.18 30 20 30 55 1.07 0.66 2.61 0.49 x 0.49 700 not fitted 6 – 11 12 4 – 6
I8-20S 0.18 30 20 30 55 1.07 0.66 3.58 0.49 x 0.49 800 fitted as standard 0.5 6 – 11 12 4 – 6
I8-20A
I8-20G
0.18 30 20 30 55 1.07 0.66 4.31 0.49 x 0.49 1230 fitted as standard 2 6 – 11 12 7 – 9
I8-40 0.36 40 30 40 70 1.24 0.92 3.29 0.56 x 0.56 920 not fitted 8 – 14 12 8 – 10
I8-40S 0.36 40 30 40 70 1.24 0.92 3.93 0.56 x 0.56 1250 fitted as standard 0.5 8 – 14 12 8 – 10
I8-40A
I8-40G
0.36 40 30 40 70 1.24 0.92 4.40 0.56 x 0.56 1520 fitted as standard 2 8 – 14 12 9 – 11
I8-55 0.54 50 40 50 90 1.52 0.92 3.60 0.72 x 0.83 1500 not fitted 10 – 18 12 10 – 12
I8-55S 0.54 50 40 50 90 1.52 0.92 4.02 0.72 x 0.83 1670 fitted as standard 0.5 10 – 18 12 10 – 12
I8-55A
I8-55G
0.54 50 40 50 90 1.52 0.92 4.48 0.72 x 0.83 2100 fitted as standard 2 10 – 18 12 10 – 13
I8-75 0.75 50 50 60 100 1.61 1.19 3.62 0.99 x 0.91 2200 not fitted 10 – 20 12 10 – 14
I8-75S 0.75 50 50 60 100 1.61 1.19 4.03 0.99 x 0.91 2150 fitted as standard 0.5 10 – 20 12 10 – 14
I8-75A
I8-75G
0.75 50 50 60 100 1.61 1.19 4.68 0.99 x 0.91 2450 fitted as standard 2 10 – 20 12 10 – 15
I8-140A
I8-140G
1.35 100 100 125 150 2.54 1.10 4.18 1.45 x 0.75 3100 fitted as standard 2 20 – 30 12 14 – 19
I8-200A
I8-200G
I8-M200
1.92 150 100 180 200 250 3.07 1.37 4.39 2.04 x 1.06 5000 fitted as standard 2 30 – 50 12 20 – 25
I8-250A
I8-250G
I8-M250
2.40 175 150 220 250 300 3.59 1.39 4.64 2.53 x 1.06 8000 fitted as standard 2 35 – 60 12 25 – 30
I8-700A
I8-700G
I8-M700
6.75 600 300 400 500 800 6.04 1.91 5.75 4.58 x 1.50 15000 fitted as standard 2 120 – 160 12 40 – 50
I8-1000A
I8-1000G
I8-1000M
8.70 700 400 500 600 1000 6.54 1.84 5.37 4.00 x 1.50 21500 fitted as standard 2 140 – 200 12 40 – 50

ENHANCED MEDICAL RANGE – All feature additional safety features, high powered ID fans and stainless steel exterior shell as standard.

I8-M15 0.13 20 0.75 0.75 2.72 0.50 x 0.31 652 fitted as standard 0.5 4 12 4 – 5
I8-M20 0.18 20 1.07 0.66 4.31 0.49 x 0.49 1230 fitted as standard 2 4 12 7 – 9
I8-M40 0.36 30 1.24 0.92 4.40 0.56 x 0.56 1520 fitted as standard 2 6 12 9 – 11
I8-M50 0.54 40 1.52 0.92 4.48 0.72 x 0.83 2100 fitted as standard 2 8 12 10 – 13
I8-M70 0.75 50 1.61 1.19 4.68 0.99 x 0.91 2450 fitted as standard 2 10 12 10 – 15
I8-M80 0.57 70 2.08 1.10 3.84 0.55ø 2500 fitted as standard 2 14 12 15 – 20
I8-M120 1.25 100 1.85 1.11 8.10 0.64 x 0.54 6000 fitted as standard 2 20 12 13 – 18

All models (except Sirocco) feature temperature control/monitoring as standard.
* – Burn rates dependent on atmosphreic conditions, waste streams, moisture content and calorific values. Data above is indicative ONLY and is based on optimum combustion conditions, operating experience and using high-grades of waste in each category. Actual results can vary by up to 50%.
** – Gas time is the rentention/residency time of gases in the secondary chamber.